- 您现在的位置:首页 >> 产品中心 >> 标准物质 >> 加拿大矿产科学室(CCRMP)加拿大矿产科学室(CCRMP)
-
-
中文名称:火法冶金磨机进料分分析标准物质
英文名称:Pyrometallurgical Mill Feed订货以英文名称为准。
产品编号:INM-1CAS:/
品牌:CCRMP产地:加拿大
标准值:见证书分子式:/
规格 市场价(元) 折后价(元) 供货周期 数量 加入购物车 50g 0.00 0.00 3-4周 加入购物车
-
产品详细介绍
INM-1火法冶金磨机进料分分析标准物质Pyrometallurgical Mill Feed
INM-1 Certified Values
Constituent Unit Mean Within-Lab Standard
Deviation Between- Lab Standard
Deviation 95% confidence limit
S % 22.17 0.051 0.24 ± 0.20
INM-1 Informational Values
Constituent Unit Mean
Cu % 25.5
Fe % 0.51
Ni % 48.0
SiO2 % 0.1
Description
INM-1 is nickel-copper sulphide matte donated by International Nickel Company Limited in Copper Cliff, Ontario, Canada. The raw material was passed through a Denver roller, sieved, and blended to obtain 40 kg of a minus 106 micron (150 mesh) product. The yield was 93%. The material comes in glass bottles containing 50g each. This is the only size available. Each bottle was sealed under nitrogen in a laminated aluminum foil-mylar pouch to prevent oxidation.
Intended use
INM-1 is suitable for the analysis of sulphur in pyrometallurgical feed materials using a barium sulphate precipitation method. Examples of intended use are for quality control in the analysis of samples of a similar type, method development, arbitration and the calibration of equipment.
Instructions for use
The assigned values pertain to the date when issued. CANMET-MMSL is not responsible for changes occurring after receipt by the user. INM-1 should be used “as is”, without drying. The contents of the bottle should be thoroughly mixed before taking samples. The contents of the bottle should be exposed to air for the shortest possible time. After opening the sealed pouch, the bottle should be kept in a dessicator, or preferably, resealed under nitrogen in a new heat-sealed laminated foil pouch to prevent oxidation.
Handling instructions
Normal safety precautions for handling fine particulate matter are suggested, such as the use of safety glasses, breathing protection, gloves and a laboratory coat.
Homogeneity
A formal assessment of homogeneity was not performed on INM-1. The assumption that the material is homogeneous is supported by the fact that the within-laboratory standard deviation obtained in the interlaboratory measurement program for INM-1 is smaller than that obtained with similar materials. The participants in the interlaboratory measurement program for INM-1 used sample sizes ranging from 0.15 to 1-g. Use of a smaller sub-sample will invalidate the use of the certified value and associated parameters.
Certified values
Ten laboratories from the smelting industry and government participated in the interlaboratory certification program. Sulphur was analysed using a barium sulphate precipitation method. A one-way analysis of variance was used to estimate the consensus value and associated statistical parameters. Sulfur was given certified value and a further four constituents had informational values assigned.